RT-1500

Specification:
- Valves: spring and weighted safety valve
 - Size: 1/2" to 2" thereaded valves and 1" to 10" flanged valves
 - Medium: water and nitrogen gas
 - Tests: set pressure and seat tightness
 - Pressure: up to maximum 1500 psi (100bar)
 - Pump: air driven piston pump
 - Clamping: mechanical
 - Pressure Gauge: 4 pressure gauges with quick coupling connection in varying range
 - Valve seat: Stainless steel seal plate with NBR O-rings
 - Adaptors: for male and female thread connection from 1/2" to 2"
 - Safety factor: 4:1
 

Options:
- Bubble counter
 - Safety shield, made of polycarbonate plastic
 - Computerized data managment
 - Air driven gas booster/gas reseiver
 - Air amplifier
 - Water softener
 - Air compressor
 - Stainless steel water tank
 
Utilities:
- Compressed air line of 100 psi (7bar)
 - Water and sewage lines
 - Nitrogen bottle
 - Electricity 220 VAC, 50 Hz
 